Reflexion Defense System Upgrades

Megasonic Module:

  • Mega liquid recirculation status monitor
    • Reflexion : cannot detect flow
    – Install the digital flow sensor at the pump outline end to detect the actual flow
    • LK : can detect flow
image14

LK

image12i

Reflexion

  • Mega tank level status monitor
    • Reflexion : open loop control
    – Install Level Detection Optical Fiber module inside the tank wall to confirm liquid level height
    • LK : cloose loop control
image16

Optical Fiber

image15

Optical Fiber

image19

Sensor Position

Megasonic Module:

  • Mega idle roller rotation status monitor
    • Reflexion : cannot detect rotation
    – Modify idle roller and add viewport, when present sensor starts, laser will determine the notch rotation
    • LK : cannot detect rotation
image22

As is

image23i

To

  • Test simulation photos
image24
image25i

The value of the feedback will be lower than the set value when turning to Notch

Brush Module:

  • Brush chemical / DIW flow monitor
    • Reflexion : open loop control
    – Install the PFA turbo flow meter at the end of the pipe. When the solenoid valve is started, it detects whether the flow meter receives the value within the upper and lower limits
    • LK : close loop control
image32
image35i

System Construction: